Relays Liquid Level Relays
LL   Liquid Level Control Relay - LL Series

The LL Series Relay is a factory configurable multi-purpose device capable of sensing conductive non hazardous fluids with low voltage contact probes.  It has five factory settable modes of operation:

  • LLF - Liquid Level Fill control
  • LLD - Liquid Level Drain control
  • LLA - Dual High/Low Alarm or Simplex Seal and Temp Stat Failure Relay
  • LLO - Dual Seal Failure Relay
  • LLC - Dual Temp Stat Failure Relay

In addition to the five operational modes listed above, it has four supply voltage range models:

  • 12A :     11  to 16VAC
  • 24A :     20 to 29VAC
  • 120A :   100 to 125VAC
  • 240A : - 200 to 240VAC

Provides relay latching for tank fill or drain operations. Adjustable sensitivity.  Multiple operation options.

You must select from the options below to complete your order of this item.

Prices shown are OEM Net


Quantity Price / Each


  Options - Customize it
  Operation - Choose operating mode
LLA - High & Low Dual Alarm
LLC - Dual Temp Stat Failure Relay
LLO - Dual Seal Failure Relay
LLD - Tank Drain Applications
LLF - Tank Fill Applications
  Supply Voltage - Choose unit rated for your power supply
 
Application
Application
Operation
Operation
Specifications
Specifications
Ordering Information
Ordering Information
Product Cut Sheet
Product Cut Sheet
  • Duplex pumping
  • Lift stations
  • Pumps or Compressors
  • Level sensing (Float or Probe)
  • Combustible or Hazardous locations
  • Simplex pumping
  • Liquid Level Sensing The LL F/D/A/O/C senses conductive non hazardous fluids with low voltage contact probes. Internal logic circuitry controls the relay latching for tank Fill or Drain operations. Three diagnostic LEDs indicate the input and output relay states. The sensitivity is adjustable to control effects of liquid wickers from the level probes. The Alarm version operates as a Dual High and Low Level Alarm or it may be operated as either a High or Low Alarm. A delay timer reduces wave effects.

    Input Supply Voltage

    12 or 24 VAC, 20%
    120 or 240 VAC, 20%

    Frequency

    50/60 Hz

    Power Consumption

    2 VA

    Sensitivity Range

    5K to 100KO

    Pick-Up & Drop-Out Delays

    5 Sec. fixed

    Max. Probe Voltage (AC)

    16 V

    Output Rating @ 25șC

    5 A @ 250 VAC
    10 A @ 120 VAC
    30 VDC 300W (D.C.)
    1600 VA (A.C.) Max. switching power (resistive)
    100,000 Full Load Electrical Cycles
    20,000,000 Mechanical Cycles

    Indicators

    1 Relay Status LED
    2 Input Status LEDs: Closed Connection On

    Mounting

    Plug-In

    Termination

    8 Pin (Octal)

    Packaging

    Dust Cover

    Weight

    9 oz

    Ambient Operating Temperature

    0 to 40 șC

    Ambient Storage Temperature

    -40 to 85 șC

    Certifications

    <!--



UL E71902 Standard-->


    R-K Model

    LL

    Operation

    A - High & Low Dual Alarm, pin 6 is NO input & pin 8 is NC input
    C - Dual Alarm, 6 & 8 are NC inputs
    D - Tank Drain Applications
    F - Tank Fill Applications
    O - Dual Alarm, 6 & 8 are NO inputs

    Supply Voltage

    12A - 11 to 16 VAC
    24A - 20 to 29 VAC
    120A - 100 to 125 VAC
    240A - 200 to 240 VAC

    Ingram Products Inc.   provides free individual PDF catalog cutsheets on all our products. In addition to the product data you can view right here on the site, the cutsheets provide dimensioned drawings, mounting hole templates and other useful information.


    If you have trouble opening our PDF documents, you may wish to download the latest version of Adobe Viewer.
    Help me get the latest version of Adobe Reader.

    The LL F/D/A/O/C senses conductive non hazardous fluids with low voltage contact probes. Internal logic circuitry controls the relay latching for tank Fill or Drain operations. Three diagnostic LEDs indicate the input and output relay states. The sensitivity is adjustable to control effects of liquid wickers from the level probes. The Alarm version operates as a Dual High and Low Level Alarm or it may be operated as either a High or Low Alarm. A delay timer reduces wave effects.

       When purchasing this product, you may want to consider this item as well.... - Hookup and mounting hardware.
    Octal Relay Socket, DIN rail or surface mounting
    Octal Relay Socket, DIN rail or surface mounting

    Socket for mounting and electrically connecting our 8 pin timer relays. DIN rail or screw mountable. Electrical connection using screw terminals. Will work with any 8 pin relay. UL recognized and CE certified.
    Price shown is OEM net.


    Price: $2.90

    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  